Sydney Data Centre Infrastructure Map

    53 facilities and 15 substations: 27 operational, 9 under construction, 17 planned. Data as at 2 November 2026.

    Tap a site for details. Use Controls to filter by status or operator.

    Changes since October 2026

    All Sydney data centres tracked

    The facilities on the map above, as a list. Operator names link through to their Certified Strategic profile, or to their listing in the directory.

    FacilityOperator, suburbMW, status
    AirTrunk SYD3AirTrunkHuntingwood400 MWTotal campus capacity, measure not statedOperational
    AirTrunk SYD1AirTrunkHuntingwood130 MWTotal campus capacity, measure not statedOperational
    AirTrunk SYD2AirTrunkLane Cove West120 MWTotal campus capacity, measure not statedOperational
    NEXTDC S3/S6NEXTDCArtarmon93.5 MWOperational
    NEXTDC S2NEXTDCMacquarie Park30 MWOperational
    Digital Realty SYD10/SYD11Digital RealtyErskine Park25 MWOperational
    Telstra InfraCo St LeonardsTelstra InfraCoSt Leonards20 MWOperational
    Macquarie DC IC2/IC3Macquarie Data CentresMacquarie Park18 MWOperational
    NEXTDC S1NEXTDCMacquarie Park16 MWOperational
    GreenSquareDC SYD1GreenSquareDCNorwest15 MW15MW first stage, measure not stated, operator's figureOperational
    DCI SYD01DCI Data CentresEastern Creek11 MWOperational
    Equinix SY6EquinixSilverwater9 MWIT load, 2012 contract figureOperational
    Macquarie DC IC1Macquarie Data CentresHaymarket2 MWIT load, builtOperational
    5G Networks NSDC5G NetworksSt Leonards1.5 MW1.5MW power availability, operator's figureOperational
    5G Networks SDC5G NetworksPyrmont1.5 MW1.5MW of power, measure not stated, operator's figureOperational
    AWS Eastern CreekAWSEastern CreekCapacity not publishedOperational
    AWS Smeaton GrangeAWSSmeaton GrangeCapacity not publishedOperational
    CDC EC1-EC4CDC Data CentresEastern CreekCapacity not publishedOperational
    CDC EC5/EC6CDC Data CentresEastern CreekCapacity not publishedOperational
    DigiCo SYD1DigiCoUltimoCapacity not publishedOperational
    Equinix SY1/SY2EquinixMascotCapacity not publishedOperational
    Equinix SY3EquinixAlexandriaCapacity not publishedOperational
    Equinix SY4/SY5EquinixAlexandriaCapacity not publishedOperational
    Keppel Gore HillKeppel DCArtarmonCapacity not publishedOperational
    Unisys RhodesUnisysRhodesCapacity not publishedOperational
    Vocus SYD01Vocus CommunicationsAlexandriaCapacity not publishedOperational
    Vocus SYD04Vocus CommunicationsRoseberyCapacity not publishedOperational
    CDC Marsden ParkCDC Data CentresMarsden Park504 MWUnder construction
    NEXTDC S4NEXTDCHorsley Park365 MWIT load, full campus (250MW in progress)Under construction
    Project Blue TongueOperator not namedWetherill Park132 MWIT load, two buildings (160.85MW maximum power)Under construction
    Goodman SYD01Goodman GroupArtarmon80 MWIT load at the 2025 consent (consent now 90MVA)Under construction
    DCI SYD02DCI Data CentresEastern Creek63 MWIT load, approved capUnder construction
    Starwood/Doma/TelstraStarwood/Doma/TelstraMinchinbury62 MWUnder construction
    DigiCo SYD1 expansionDigiCoUltimo52 MW52MW expansion, measure not stated, operator's figureUnder construction
    Macquarie IC3 Super WestMacquarie Data CentresMacquarie Park47 MWUnder construction
    Microsoft Kemps CreekMicrosoftKemps CreekCapacity not publishedUnder construction
    AirTrunk/ISPT Mamre RdAirTrunk / ISPTKemps Creek1,000 MW1GW power capacity on the NSW Planning Portal; the application's own figures run from 600MW to 1.2GWPlanned
    NEXTDC S7 (OpenAI)NEXTDCEastern Creek550 MWIT load, planned (612MW in the planning application)Planned
    STACK SYD01STACK InfrastructureErskine Park450 MWTotal power consumption, proposal under assessmentPlanned
    Goodman Project AtlasGoodman GroupEastern Creek348 MWTotal power consumption (500MVA supply)Planned
    Stockland Kemps CreekStocklandKemps Creek342 MWIT load, 342 to 360MW range (amended scheme)Planned
    Microsoft Honeman CloseMicrosoftHuntingwood96 MWIT load, approved (140MVA total)Planned
    Goodman Project DukeGoodman GroupMascot85 MWIT load, approved (120MW total power)Planned
    GreenSquareDC SYD1 Stage 2GreenSquareDCNorwest80 MWPlanned
    NEXTDC S5NEXTDCMacquarie Park80 MWIT load, plannedPlanned
    ISPT Julius AvenueISPTNorth Ryde76 MWIT load, amended scheme (120MW total power)Planned
    Digital Realty SYD12Digital RealtyMacquarie Park70 MWTotal power consumption, proposalPlanned
    Goodman Project PlutoGoodman GroupGuildford West68 MWIT load, approved (100MW total power)Planned
    AWS Gregory HillsAWSGregory Hills53 MWPlanned
    Stockland/EdgeConneX MParkStockland / EdgeConneXMacquarie Park51.4 MWIT load, approved building (76.4MW maximum power)Planned
    192 Narellan Road, Campbelltown (planned)Operator not namedCampbelltown100MW total loadTotal load, proposal (no IT load published)Planned
    AIMS Bella VistaAIMS CapitalBella VistaCapacity not publishedPlanned
    Stockland Wetherill ParkStocklandWetherill ParkCapacity not publishedPlanned

    Substations on this map

    Figures are as each network publishes them. Networks rarely publish spare capacity, so cells without a published figure say not published.

    Sydney West Bulk Supply PointNetworkTransgridFirm rating (N-1)not publishedPeak demandnot publishedNetwork's own figure64 MW now, 0 MW in 5 yearsAvailable capacity for load, 132 kVSourceTransgrid Transmission Annual Planning Report portal, September 2026
    Kemps Creek SubstationNetworkTransgridFirm rating (N-1)not publishedPeak demandnot publishedNetwork's own figurenot publishedSourcenot published
    Vineyard Bulk Supply PointNetworkTransgridFirm rating (N-1)not publishedPeak demandnot publishedNetwork's own figure130 MW now, 0 MW in 5 yearsAvailable capacity for load, 132 kVSourceTransgrid Transmission Annual Planning Report portal, September 2026
    Macquarie Park Zone SubstationNetworkAusgridFirm rating (N-1)114.32 MVAPeak demand61.84 MVAsummer 2024/25Network's own figurenot publishedSourceAusgrid Distribution and Transmission Annual Planning Report 2025, Substation Capacity and Demand Forecast, December 2025
    Lane Cove Switching StationNetworkAusgridFirm rating (N-1)not publishedPeak demandnot publishedNetwork's own figurenot publishedSourcenot published
    Mason Park Switching StationNetworkAusgridFirm rating (N-1)not publishedPeak demandnot publishedNetwork's own figurenot publishedSourcenot published
    Alexandria Subtransmission SubstationNetworkAusgridFirm rating (N-1)142.9 MVAPeak demand24.54 MVAsummer 2024/25Network's own figurenot publishedSourceAusgrid Distribution and Transmission Annual Planning Report 2025, Substation Capacity and Demand Forecast, December 2025
    Eastern Creek SubstationNetworkEndeavour EnergyFirm rating (N-1)45 MVAPeak demand21.52 MVA2025Network's own figurenot publishedSourceEndeavour Energy Distribution Annual Planning Report 2025 portal, December 2025

    About This Map

    This map tracks data centres across Greater Sydney, from operating campuses to sites under construction and projects that have been announced, lodged or approved. Capacity is IT load in megawatts unless the site's entry names another measure. Figures are as the operator or the planning application states them, and sites without a published figure are marked "Capacity not published".

    Records come from operator announcements and ASX releases, the NSW Planning Portal, and the planning reports published by Transgrid, Ausgrid and Endeavour Energy. Each record carries the source it came from.

    The map is refreshed on the first business day of each month, and the date above the map is the date the data was last checked, not the date you opened the page.

    Substation locations: NSW Spatial Services. Constraint and augmentation detail: Transgrid Western Sydney RIT-T reports 2024, Transgrid network capacity update June 2026, Ausgrid Wallumatta contingent project application 2025, NSW distributors' submission to the NSW data centres inquiry 2026.

    Map researched and maintained by CertifiedStrategic.com.

    Related Analysis

    Capacity

    Australian capacity requirements

    For neoclouds, AI labs and enterprises planning an Australian deployment. We shortlist sites against your GPU platform, scale, market and ready-for-service date. Operators with capacity coming online are welcome to get in touch.

    Connect on LinkedIn

    Every field is optional except a way to reach you. Share only what you are comfortable with; nothing is passed on without your agreement.

    Keep reading the market

    Get The Strategic Brief in your inbox every Thursday.

    The leading Australian data centre and AI infrastructure newsletter.

    One email a week. Unsubscribe in one click.